<?xml version="1.0" encoding="UTF-8"?><rss xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:content="http://purl.org/rss/1.0/modules/content/" xmlns:atom="http://www.w3.org/2005/Atom" version="2.0"><channel><title><![CDATA[National Lock Supply]]></title><description><![CDATA[National Lock Supply]]></description><link>https://national-lock-supply.hashnode.dev</link><generator>RSS for Node</generator><lastBuildDate>Sat, 31 Oct 2026 09:07:37 GMT</lastBuildDate><atom:link href="https://national-lock-supply.hashnode.dev/rss.xml" rel="self" type="application/rss+xml"/><language><![CDATA[en]]></language><ttl>60</ttl><item><title><![CDATA[Access Control Hardware 101: Readers, Electric Strikes & Power Supplies]]></title><description><![CDATA[If you’re in IT or Facilities, access control is where the network meets the door. This skimmable guide hits the must-know components and the compatibility…]]></description><link>https://national-lock-supply.hashnode.dev/access-control-hardware-101-readers-electric-strikes-and-power-supplies</link><guid isPermaLink="true">https://national-lock-supply.hashnode.dev/access-control-hardware-101-readers-electric-strikes-and-power-supplies</guid><category><![CDATA[locks]]></category><category><![CDATA[keys]]></category><category><![CDATA[Security]]></category><category><![CDATA[doors]]></category><dc:creator><![CDATA[Felix Anderson]]></dc:creator><pubDate>Sun, 21 Sep 2025 20:58:30 GMT</pubDate><enclosure url="https://cdn.hashnode.com/res/hashnode/image/upload/v1758488043739/47254059-6e28-4644-a640-94491bbcfa2d.webp" length="0" type="image/jpeg"/><content:encoded><![CDATA[<p>If you’re in IT or Facilities, access control is where the network meets the door. This skimmable guide hits the <strong>must-know components</strong> and the compatibility checks that keep projects online and compliant.</p>
<h2 id="heading-tldr">TL;DR</h2>
<ul>
<li><p><strong>Readers</strong> capture credentials (cards/phones/PIN) and talk to your controller.</p>
</li>
<li><p><strong>Electric strikes</strong> secure the latch so you control entry while preserving free egress.</p>
</li>
<li><p><strong>Power supplies</strong> keep everything reliable during surges and outages.</p>
</li>
</ul>
<h2 id="heading-readers-what-identifies-people">Readers (what identifies people)</h2>
<ul>
<li><p><strong>Tech options:</strong> 125 kHz prox (legacy), 13.56 MHz smart (DESFire/iCLASS), mobile creds (BLE/NFC), PIN pads.</p>
</li>
<li><p><strong>Protocol:</strong> Prefer <strong>OSDP v2</strong> over Wiegand for encrypted, supervised communication.</p>
</li>
<li><p><strong>Tips:</strong> Standardize one credential type; confirm reader↔controller bit formats; plan for mobile if your org uses MDM.</p>
</li>
</ul>
<h2 id="heading-electric-strikes-what-actually-moves-the-door">Electric strikes (what actually moves the door)</h2>
<p>An electric strike replaces/augments the frame strike and works with your latchset—ideal when you want mechanical egress with controlled entry.</p>
<ul>
<li><p><strong>Fail mode:</strong></p>
<ul>
<li><p><em>Fail-secure</em> (stays locked on power loss) for perimeter/security.</p>
</li>
<li><p><em>Fail-safe</em> (unlocks on power loss) where code requires free egress on outage.</p>
</li>
</ul>
</li>
<li><p><strong>Match the opening:</strong> Cylindrical vs. mortise latch, frame material (HM/wood/aluminum), fire rating.</p>
</li>
<li><p><strong>Power profile:</strong> Check inrush and holding current; size wire to limit voltage drop.</p>
</li>
</ul>
<p>Shop spec-ready <a target="_blank" href="https://nationallocksupply.com/electric-strikes/"><strong>electric strikes</strong></a> that include multiple faceplates and support both fail-safe and fail-secure wiring.</p>
<h2 id="heading-power-supplies-what-keeps-it-alive">Power supplies (what keeps it alive)</h2>
<p>Clean, right-sized power prevents nuisance failures and inspection headaches.</p>
<ul>
<li><p><strong>Centralized vs. distributed:</strong></p>
<ul>
<li><p><em>Distributed</em> near the door = easier voltage drop management, simpler troubleshooting.</p>
</li>
<li><p><em>Centralized</em> = simpler UPS/battery and monitoring—plan for cable length and inrush.</p>
</li>
</ul>
</li>
<li><p><strong>Must-haves:</strong> Battery backup, supervised outputs, fire alarm interface (FAI), and 30–50% capacity headroom.</p>
</li>
<li><p><strong>POE caveat:</strong> Some controllers can drive locks via POE(+); confirm budget for <strong>inrush</strong>.</p>
</li>
</ul>
<p>Consider monitored <a target="_blank" href="https://nationallocksupply.com/electronic-hardware/power-supply/"><strong>access control power supplies</strong></a> with fused/individually protected outputs and proper battery charging.</p>
<h2 id="heading-quick-compatibility-checklist-clip-this">Quick compatibility checklist (clip this)</h2>
<ul>
<li><p><strong>Door type &amp; label:</strong> Fire-rated? Egress path?</p>
</li>
<li><p><strong>Locking method:</strong> Strike vs. maglock (strike is simpler for latch doors).</p>
</li>
<li><p><strong>Reader ↔ controller:</strong> OSDP v2, credential format, facility codes.</p>
</li>
<li><p><strong>I/O &amp; sensors:</strong> Door position, REX, supervised loops (EOL).</p>
</li>
<li><p><strong>Power math:</strong> Sum loads, add inrush, then +30–50% headroom; check cable length/voltage drop.</p>
</li>
<li><p><strong>Fail mode:</strong> Document fail-safe/fail-secure per AHJ.</p>
</li>
<li><p><strong>Network:</strong> POE budgets, VLAN, controller reachability.</p>
</li>
</ul>
<h2 id="heading-common-good-setups">Common “good” setups</h2>
<ul>
<li><p><strong>Standard office door:</strong> OSDP reader + cylindrical latch + <strong>electric strike</strong> (fail-secure) + local PSU w/ 8-hour battery.</p>
</li>
<li><p><strong>Fire-rated corridor door:</strong> Listed hardware, closer, <strong>electric strike</strong> (permitted type) + centralized PSU with FAI.</p>
</li>
<li><p><strong>Storefront (wind load):</strong> Top-jamb closer, heavy-duty <strong>electric strike</strong>, distributed PSU to minimize voltage drop.</p>
</li>
<li><p><strong>Healthcare interior:</strong> OSDP reader + mortise lock + strike (fail-safe) + PSU; consider delayed egress relays if policy allows.</p>
</li>
</ul>
<h2 id="heading-fast-answers">Fast answers</h2>
<p><strong>OSDP or Wiegand?</strong> OSDP v2 for encryption and supervision—future-proof it.<br /><strong>Strike or maglock?</strong> On latch doors, use a <strong>strike</strong> to keep egress intuitive.<br /><strong>Why do doors “randomly” fail?</strong> Undersized PSUs, voltage drop, or missing flyback suppression on DC loads.</p>
<h2 id="heading-wrap-up">Wrap-up</h2>
<p>Treat access control like any enterprise system: standardize readers, choose the right strike behavior, and overspec clean power. Do that, and the door just…works.</p>
]]></content:encoded></item></channel></rss>